Calibration Panel

See also Calibration overview

Lens calibration

Auto-calibration: Automatically calibrate lenses using a non-uniform specimen with distinct features

Edit Lens: Edit or delete an existing software lens

New Lens: Create a new software lens

Parcentric Parfocal: Conduct parcentric and parfocal calibration

Recalibrate Lens: Manually calibrate (grid tune) lenses using a calibration-grid slide or an image of a calibration grid slide

Calibration tools

Bright grid

Toggle the brightness of the grid display between maximum and medium brightness (available when Show Grid is enabled). This may be helpful when illumination levels are high.

Fast focus

Open the Fast Focus Adjustments window. Use the controls to rapidly move the stage in the Z orientation. This may be helpful for quickly moving specimens closer to an in-focus position.

Focusing in the negative direction or down through the tissue moves the stage closer to the objective lens. To avoid damaging the objective and/or the specimen, verify that you have adequate clearance before attempting large movements in the negative direction.

Focus knobs on the microscope

  • It is possible to use the coarse focus on the microscope, but keep in mind that these movements in the Z-axis are not recorded by Neurolucida unless your system has a focus-position encoder. This would be problematic for a 3D reconstruction or a multi-section neuron tracing since the Z-axis information is essential to the accuracy of your data.
  • Unless you have an internal Z motor on your microscope, we recommend that you avoid using the focus knobs on the microscope after the initial set-up of the slide on the microscope.

Do not use the fine focus knob on the microscope if you have a focus motor, as this can strip the gears of the focus motor.

Grid preferences

Open Display Preferences. In the Tracing window section, you can set the grid spacing and other grid properties.

Note that at low magnifications, the grid can become too dense to see the specimen. To prevent this, the grid is automatically turned off when the spacing between grid lines drops below 4 pixels.

Movement preferences

Open the Movement preferences window.

Set stage Z

Manually set the current Z value.

  • In the Stage Z Position dialog box that opens, enter a new value, and then click OK.

  • Click ALT+S to quickly set the Z meter position to 0.

Show grid

Toggle display of a rectangular grid overlay on and off. Note that:

  • The grid is anchored at the reference point and moves along with the tracing when in joy track mode.

  • The Grid spacing (µm) can be changed in the Tracing window section of Display Preferences.

  • Displaying the grid may be useful for checking the lens calibration or to divide a region into fixed areas for further analysis.

Show labels

Toggle display of the grid coordinates on and off (available when Show Grid is enabled)

Grid coordinates are generated as follows:

  • A0 is the coordinate of the reference point.
  • Letters are in alphabetical order to the right of the reference point, and numbers increase below the reference point.
  • Grid intersections to the left of the reference point are listed with negative letters.
  • Intersections above the reference point are listed with negative numbers.