Enable Automatic Moves To Top Of Section | Moves to the top of the section when moving to a new sampling site. |
Enable Automatic Moves To Top Of Disector | Moves to the top of the disector (3D counting frame) after the top of the section has been marked. |
Disable The AutoMove Box During Stereological Procedures | See AutoMove |
Show Cavalieri Grid In Show Whole File Mode |
When the entire file is shown, the Cavalieri grid is superimposed on the tracing. |
Display Cavalieri Grid Using Circles | Draws circles around every fourth Cavalieri point. |
Set Probe Color | Choose a color that stands out against the background for the probe shape (cross-hair, line, cycloid, etc.) |
Change Tick Mark Style/Size | Choose a marker type and a size that help you visualize the probe's results better. |
See Counting Frames and Counting rules for the counting frame
Display Counting Frame With Extended Exclusion Lines | Extends the exclusion lines beyond their normal range. |
Mark Center Point of Counting Frame | Adds a center point to each counting frame. |
Use Not In Z Limit Color When Above or Below Disector | When you are above or below the disector, Stereo Investigatorchanges the color of the counting frame from the default colors (typically red and green) to a single color. These colors can be changed under Counting Frame Colors. |
Restrict Placing Markers To Inside of Counting Frame |
Markers can't be placed outside of the counting frame. |
Restrict Placing Markers To Acceptance Area | Markers can only be placed in the counting frame excluding the guard zones. |
Expand All Calculations When Viewing Results | Displays all the categories in the left panel of the Sampling Results window. See Display Probe Run List |
Display Partial Calculations of Formulas | Controls the display of the planimetric variance details in an SRS probe; when checked, displays the covariogram values (A, B and C). |
Fill Bottom Entries of Columns With Zeroes | If this option is not selected, cells with no recorded values are blank. |
Sort Sections In Ascending Order | Applies to the display of probe runs. |
Display Planimetric Results | In the Sampling Results window. |
CE Selections | See "Coefficients of Error" |
Only Display Gundersen CE If 3 or More Runs Exist | Since the Gundersen CE takes into account values from neighboring sections, it is only valid if 3 or more runs have been performed. This option keeps invalid Gundersen CE values from being displayed. It may be helpful to turn this option off during a pilot study to obtain a rough estimate of the CE. |
Display Raw Data Report | Includes the number of counts for each sampling site in each probe run. |
Display Section Order Report | Lists all sections in order of their actual Z position. |
Only the probes checked appear on the default Probes menu.
Controls Systematic Random Sampling options.
Exclude nested contours: Nested contours are closed contours contained entirely within another contour. When you select this option, the interior of the nested contours is excluded from the probe layout.